logo
منزل المنتجاتمستشعر الغاز

YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety

شهادة
الصين ShenzhenYijiajie Electronic Co., Ltd. الشهادات
الصين ShenzhenYijiajie Electronic Co., Ltd. الشهادات
ابن دردش الآن

YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety

YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety
YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety

صورة كبيرة :  YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety

تفاصيل المنتج:
Place of Origin: USA
اسم العلامة التجارية: YJJ
Model Number: ES4-H2S-10 ES4-H2S-100
شروط الدفع والشحن:
Minimum Order Quantity: 1
الأسعار: قابل للتفاوض
Packaging Details: Palletized
Delivery Time: 5 to 8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1500

YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety

وصف
يتراوح: 0-100 جزء في المليون حساسية: 0.8 ± 0.2 مللي أمبير/جزء في المليون
خط الأساس: <± 0.4 Ma في 20 ℃ دقة: 0.1 جزء في المليون
وقت الاستجابة: T90 ≤ 20 ثانية extenge-المدى الطويل الاستقرار ‌: <2 ٪ في الشهر
درجة حرارة التشغيل ‌: 0 - 50 ℃ شروط storge ‌: 6 أشهر
إبراز:

electrochemical hydrogen sulfide gas sensor,industrial safety gas sensor,H2S gas sensor with warranty

,

industrial safety gas sensor

,

H2S gas sensor with warranty

Product Description:

YJJ  ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used in Field of Industrial Safety

 

Features:

ES4-H2S-100 gas sensor is a high-precision hydrogen sulfide detection device, mainly applied in industrial safety, environmental monitoring and other scenarios. The following are its core parameters and usage descriptions:
Core parameters
‌Range‌: 0 - 100 ppm
‌Sensitivity‌: 0.8 ± 0.2 mA/ppm
‌Baseline‌: < ± 0.4 mA at 20℃
‌Resolution‌: 0.1 ppm
‌Response time‌: T90 ≤ 20 seconds
‌Long-term stability‌: < 2% per month
‌Operating temperature‌: 0 - 50℃
‌Storage conditions‌: 6 months (special packaging), 0 - 20℃
Applicable scenarios
Industrial Safety: Applicable to high-risk areas such as coal mines, petrochemical plants, and power plants, capable of detecting hydrogen sulfide leaks.
Environmental Monitoring: Used for monitoring in sewage treatment plants, waste incineration emissions, and other high-concentration scenarios.
Portable Detection: Portable equipment can be flexibly deployed in multi-gas integrated detection scenarios.
Notes for Attention
It is recommended to use the target gas for calibration. Cross-sensitive gases may cause measurement errors.
For long-term use, regular calibration is necessary to ensure measurement accuracy.

ES4-H2S-100 hydrogen sulfide polymer sensor describes the product characteristics

good linear response

low noise

warm-up time is short

no electrolyte leakage

low price (large order)

quick response

each sensor includes test report

German EC sensor small size, no power consumption, low cost, long life, high precision industrial grade smart polymer electrochemical gas sensor, so that smart phones, wearable devices, commercial buildings

Internal air quality monitoring, in-car air quality monitoring, medical monitoring, etc.

Industrial level technical standards, serving the civil field, to provide perceptual layer accurate data sniff out danger! Smell the poison!

performance

Sensitivity to 90 + 20 na/PPM

Plus or minus 20 na bottom current

The response time

-T50< 10s

-T90< 30s

Range 100 ppm500ppm1000ppm

Repetitive 1%

Minimum detection limit ≤1ppm

Resolution (16-bit ADC)0.1ppm

Maximum load 200ppm1000PPM2000PPM

Linear range is 200ppm1000PPM2000PPM

The environment

Temperature range -40to50℃

Relative humidity range (non-condensing) 10to95%rH

Pressure range 800-1200hPA

operation

Operating principle three electrode electrochemical formula

Bias 0 mv

The recommended load resistance is 100Ω

Heating time < 20s

life

Long-term stability < 1% month

Zero drift (in clean air) < 2ppm

Storage conditions 0-20℃

Expected working life > 3 years

Storage time: 6 months

The warranty period is 12 months

encapsulation

Packaging material ABS

Weight & lt; 6g

Order no. 01 - ES4 - H2S - 100-01

 

Specifications:

Standard packaging metal
Detection of gas Methane, natural gas, methane
Detection of concentration 300~10000ppm
Circuit voltage ≤24V DC
heating voltage 5.0V±0.1V AC or DC

 

YJJ ES4-H2S-10 ES4-H2S-100 Electrochemical Hydrogen Sulfide Gas Sensor Is Used In Field Of Industrial Safety 0

تفاصيل الاتصال
ShenzhenYijiajie Electronic Co., Ltd.

اتصل شخص: Miss. Xu

الهاتف :: 86+13352990255

إرسال استفسارك مباشرة لنا (0 / 3000)