logo
منزل المنتجاتمستشعر الغاز

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

شهادة
الصين ShenzhenYijiajie Electronic Co., Ltd. الشهادات
الصين ShenzhenYijiajie Electronic Co., Ltd. الشهادات
ابن دردش الآن

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor
YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

صورة كبيرة :  YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

تفاصيل المنتج:
مكان المنشأ: سويسرا
اسم العلامة التجارية: YJJ
رقم الموديل: NH3/CR-50
شروط الدفع والشحن:
الحد الأدنى لكمية: 1
الأسعار: قابل للتفاوض
تفاصيل التغليف: حزمة مربع
وقت التسليم: 5-8 أيام
شروط الدفع: L/C ، D/A ، D/P ، T/T ، Western Union ، Moneygram
القدرة على العرض: 1500

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

وصف
نطاق القياس: 0 ~ 100 جزء في المليون خدمة الخدمة: 2 سنة في الهواء
إشارة الإخراج: 90±18nA/جزء في المليون دقة: 1 جزء في المليون
نطاق درجة الحرارة: -10 درجة مئوية إلى 40 درجة مئوية وقت الاستجابة (T90): <60 ثانية
نطاق الرطوبة: 15% إلى 90% حدود: 0 جزء في المليون ± 4 جزء في المليون
إبراز:

electrochemical ammonia gas sensor,liquid ammonia leakage detector,NH3 CR-50 gas sensor

,

liquid ammonia leakage detector

,

NH3 CR-50 gas sensor

Product Description:

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

 

Features:

Ammonia gas sensor (NH3 sensor)

NH3/CR-200,NH3/MR-100,NH3/S-200,NH3/CR-1000,NH3/MR-1000,

NH3/CB-200 completely replaces 7AM, 7NH and A7AM in UK CITY

NH3/SB-200 completely replaces 3AM in UK CITY

NH3/MR-100 completely replaces 4AM in UK CITY

Technical parameters of NH3 sensor:

NH3/CR-200

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 90±18nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <60sec

Humidity range: 15%to90%

Baseline: 0ppm±4ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

NH3/MR-100

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 120±30nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <50sec

Humidity range: 15%to90%

Baseline: 0ppm±3ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

NH3/SR-200

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 90±18nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <60sec

Humidity range: 15%to90%

Baseline: 0ppm±4ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

 

Specifications:

Detection of gas NH3
range 0-20ppm
Maximum limit of measurement 250ppm
The sensitivity 1±0.25 uA/ppm

 

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor 0

تفاصيل الاتصال
ShenzhenYijiajie Electronic Co., Ltd.

اتصل شخص: Miss. Xu

الهاتف :: 86+13352990255

إرسال استفسارك مباشرة لنا (0 / 3000)

منتجات أخرى