logo
منزل المنتجاتمستشعر الغاز

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

شهادة
الصين ShenzhenYijiajie Electronic Co., Ltd. الشهادات
الصين ShenzhenYijiajie Electronic Co., Ltd. الشهادات
ابن دردش الآن

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector
YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

صورة كبيرة :  YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

تفاصيل المنتج:
مكان المنشأ: بريطانيا
اسم العلامة التجارية: CITY
رقم الموديل: CL2-A1
شروط الدفع والشحن:
الحد الأدنى لكمية: 1
الأسعار: قابل للتفاوض
تفاصيل التغليف: المنصات
وقت التسليم: 5-8 أيام
شروط الدفع: خطاب الاعتماد، D/A، D/P، T/T، ويسترن يونيون، موني جرام
القدرة على العرض: 1500

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

وصف
غاز متداخل: غازات CL2 خطأ التكرار: ± 2% على مدى 6 أشهر
إشارة الإخراج: الجهد التناظرية التكرار: < ±2 مكافئ CL2
عمر التخزين: سنتان درجة حرارة التشغيل: 0 ℃ ~+50 ℃
نوع الاستخدام: وظيفة محمولة نطاق الكشف: 0 ~ 20 جزء في المليون
إبراز:

chlorine gas electrochemical sensor 20ppm

,

portable chlorine gas detector sensor

,

YJJ CL2-A1 gas sensor

Product Description:

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

 

Features:

I. Core Parameters (Electrochemical Cl₂ Sensor)

Detected Gas: Chlorine Gas Cl₂

Measurement Range: 0 - 20 ppm (ensuring accuracy range)

Short-term Overload: Maximum tolerance 50 ppm

Sensitivity: -350 ~ -750 nA/ppm (under 10 ppm chlorine gas conditions)

Response Time T90: < 60 s (typical value < 40 s)

Resolution: < 0.02 ppm (able to detect ppb-level minor leaks)

Zero Point Current: ±0.4 ppm equivalent value

Linear Range: 0 - 5 ppm with good linearity, full range error ±1.5 ppm

Environmental Conditions

Temperature: -20℃ ~ +50℃

Humidity: 15% - 90% RH (no condensation)

Air Pressure: 80 - 120 kPa

Service Life: ≥ 24 months (original factory 24-month warranty)

Long-term Drift: Zero-point drift < 0.05 ppm/year; Sensitivity annual drift < 10%

Physical Dimensions: Φ20.2 × 16.5 mm, Weight < 6g, Standard 4-pin A-series package

Cross-Interference: SO₂ interference is small, CO, H₂, ethylene, etc. interference are extremely low, suitable for complex working conditions

II. Product Principle

Fuel cell type electrochemical sensor, chlorine gas undergoes redox reaction on the electrode surface, outputting a weak current signal, the current size is proportional to the chlorine gas concentration, the rear-end circuit converts the current into concentration values.

III. Main Applications

1) Instrument Integration (OEM preferred)

Portable chlorine gas detector, single toxic gas alarm instrument

Fixed online chlorine gas transmitter, gas monitoring probe

Industrial online monitoring module, PLC gas collection module

2) Industry Application Scenarios

Water supply / sewage treatment plants

Chlorine gas leakage monitoring in water disinfection sections, chlorination rooms, liquid chlorine steel cylinder warehouses, preventing personnel poisoning.

Chlor-alkali chemical industry, PVC synthesis production line

Pointed monitoring of minor leaks at chlorine gas pipelines, valves, reactors, liquid chlorine pumps sealing areas.

Swimming pool, swimming hall disinfection system

Monitoring of chlorine compound volatile gas concentration to ensure indoor venue occupational safety.

 fine chemicals

Tail gas and pipeline leakage detection in chlorination synthesis process workshops.

Semiconductor electronics industry

Early warning of dry etching chlorine process exhaust gas, machine gas pipeline leakage.

Environmental protection supervision, laboratory

Occupational health toxic gas detection, emergency inspection equipment.

 

Specifications:

Detected Gas CL2
Packaging 4-series
Measurement Range 0 - 20 ppm
Short-term Overload 500 ppm
Sensitivity 700 ± 250 nA/ppm

 

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector 0

تفاصيل الاتصال
ShenzhenYijiajie Electronic Co., Ltd.

اتصل شخص: Miss. Xu

الهاتف :: 86+13352990255

إرسال استفسارك مباشرة لنا (0 / 3000)

منتجات أخرى